Your worst day, your short list and your number, turned into a battery, an inverter and panels, with the paths that fit. Change any value and the page redoes the math. The four steps and their names are the ones in the book (chapter 3); this page does Steps 1 to 3.
Step 1: Name Your Worst Day
How long the grid stays down in the outage you plan for. Whole days suit a solar backup, which runs day by day; with few records, three days is a reasonable yardstick (section 4.1).
A day’s sunlight counted as hours of full sun, not hours of daylight. Find yours on the PVWatts calculator (pvwatts.nlr.gov): the lowest figure in the column in kWh/m²/day (section 4.2).
The lowest temperature of your winter at the battery’s spot. A thermometer that keeps its lowest reading, left there through a cold night, tells you (sections 4.3 and 14.3).
Step 2: List What Must Stay On
Check what must stay on during your worst day. The values are the example readings from chapter 5, in line with the typical figures in Appendix B. Replace them with the numbers on your labels or from a plug-in meter (section 5.2). For a fridge or a freezer, the meter’s 24-hour total goes straight in.
Typical figures from Appendix B
| Appliance | Typical figure |
|---|---|
| Efficient top-freezer fridge | About 1 kWh a day (ENERGY STAR) |
| Chest freezer | About 0.6 kWh a day (ENERGY STAR) |
| LED bulb, 800 lumens | About 9 watts (Federal Trade Commission) |
| Gas furnace fan, at full fire | About 450 to 560 watts (NYSERDA field study) |
Generator planning values from one public utility’s worksheet, running watts plus the extra to start: fridge or freezer 700 + 2,200; well pump, 1/3 horsepower, 1,000 + 2,000; sump pump, 1/3 horsepower, 800 + 1,300; furnace fan, 1/3 horsepower, 700 + 1,400. They are cautious values for choosing a generator, not readings of your appliances (section 1.2).
Add an appliance
What uses the most
Your number
Your number is the watt-hours your short list uses in one day. A watt-hour is watts times hours; 1,000 watt-hours make a kilowatt-hour (kWh), the unit on your electric bill (sections 1.2 and 5.3).
The starting surge is the burst of power a motor asks for as it starts: its running watts plus the extra to start. This page counts each motor’s running watts times 3, the book’s rule of thumb, unless you type the maker’s figure (sections 1.2 and 5.3).
Step 3: Match the Path to the Number
Your system size
The share of the battery’s rated capacity you can really use. For LFP it comes from the spec sheet and the warranty (90 in 100 in the book’s examples); lead-acid is typically cycled to between half and four-fifths. If the spec sheet lists the usable capacity, use 1 (section 6.1).
One allowance for the energy lost between the battery and your appliances. The book uses 0.85 for a home battery, after NREL; 0.72 for lead-acid, from a national-lab study (section 6.1).
How many dark days in a row the battery carries the list on its own. You choose them separately from the outage length: on sunny days the panels refill the battery, and what neither covers falls to the generator plan (section 6.1).
The power an inverter uses just by being on. Leave it at 0 for your system size; type it from a spec sheet when you weigh a product, and its watts times 24 join your number (sections 6.2 and 7.1).
Your darkest month’s gap and the generator
The path that fits
Five questions, answered on the table in section 7.3. Where the book gives no threshold, this page doesn’t make one up.
Figures are rounded. The book’s examples round your number first, so they can differ by a few watts.
The size comes first: whichever path you choose has to meet the same figures (section 3.3). This page shows no prices; to set real offers against your number, use the Path & Quote Comparison Spreadsheet (chapter 7).
Always
- A power station is used with extension cords. It is not wired into the home panel or used as fixed storage (section 7.1).
- Any battery that connects to the house wiring is a home battery certified to UL 9540 (sections 3.3 and 7.2).
- The connection to your home panel is installed by a licensed electrician or, where local rules let homeowners do their own work, done with a permit and an inspection (rule 5, section 10.3).
What this page can’t do
- It sizes for the outage you planned for, not for every outage.
- It doesn’t choose wires, fuses or protection: see chapter 8, the maker’s instructions and the code your state has adopted.
- It doesn’t size a backup for medical equipment that anyone at home depends on: start with their doctor (section 5.1).
- Your numbers stay in this browser, on this device. If you clear the browser’s data, they’re gone, so print your plan.
Step 4, Build and Prove It, is Part IV of the book (chapters 10 to 14).
Scenarios: what if…?
Up to three scenarios, such as “Fridge only” and “With the well pump”. Each one keeps its own values.
My Backup Plan
One page, large print, black and white: to keep by your system or with your worksheets.